No. name description
F51 Broken or short circuit in top angle sensor  
F52 Top angle error If the difference between the top angle and boom angle is more than 10 degrees, check each sensor.
F62 SL jib derrick pressure sensor error The SL jib derrick pressure sensor P1 or P2 is faulty.
F63 Broken or short circuit in SL jib derrick pressure sensor P1  
E00 FPGA error Occurs if FPGA is not functioning properly.
E01 Main unit CPU internal RAM error Displayed when a malfunction occurs in the CPU's interal RAM, in the main unit.
E02 Main unit CPU internal FROM error Occurs when the checksum value in the CPU's internal FROM does not match the calculated checksum value, in the main unit.
E03 Main unit floating decimal division by zero error Displayed when division by zero occurs during floating point calculations in the main unit or if an invalid calculation occurs.
E04 Main unit external RAM error Displayed when a malfunction occurs in the main unit external RAM.
E05 Main unit external FROM error Displayed when a checksum value in the main unit external FROM dose not match the calculated checksum value.
E06 Outrigger specifications not specified in EEPROM Occurs when replacing circuit boards.
E07 Outrigger specifications for DIP switches on circuit board dose not agree with outrigger specifications in EEPROM Occurs when replacing circuit boards.
E08 Outrigger specifications not specified on board Occurs when replacing circuit boards.
F09 EEPROM malfunction Displayed when read/write from/to EEPROM fails.
E10 Main and display units communication error Main unit and display unit cannot communicate.
E13 Software code mismatch Software codes for the main and display units do not match.
E14 Mismatch of the software code in EEPROM The software code in the EEPROM dose not match the software code in the program.
F20 ACS-COR communication error  
F21 CORDT-FT communication error  
F22 Broken or short circuit in right-front outrigger stroke  
F23 Broken or short circuit in right-rear outrigger stroke  
F24 Broken or short circuit in left-rear outrigger stroke  
F25 Broken or short circuit in left-front outrigger stroke  
F26 Engine RPM sensor error  
F27 Front iack switch error  
F29 Outrigger adjustment error Occurs when an outrigger fully retracted value is same as fully extended value or fully extended value is smaller, etc.
E33 Main unit CPU address error Displayed when an address error occurs in the main unit CPU.
If this occurs, the crane automatically stops, then the CPU stops functioning.
E34 Main unit CPU undefined error code 1 An undefined code 1 was extcuted in the main unit CPU.
If this occurs, the crane automatically stops, then the CPU stops functioning.
E35 Main unit CPU undefined error code 2 An undefined code 2 was extcuted in the main unit CPU.
If this occurs, the crane automatically stops, then the CPU stops functioning.
E40 Broken or short circuit in boom length sensor  
F40 Fully-retracted boom length error If the error is large when the fully-retracted boom length is automatically adjusted, it can be adjusted manually. When manual adjustment is performed, this is displayed briefly.
After manual adjustment, contact your authorised KATO dealer.
F41 Boom lengthoffset adjustment value error Occurs when the boom length offset adjustment value is -0.5m or less.
F42 Boom fully-retracted switch fault  
F43 Displayed when boom length zero adjustment is outside the specified range. In this case, restart from the boom fully extended length adjustment  
E45 Lθ error(E40 and E50 occur simultaneously.) Check the Lθ cable or replace the main circuit board.
F47 Fault of jib/searcher hook connection connector When the boom status is "boom","sercher hook" or "boom operation with searcher hook mounted", the voltage for jib angle detection is input into the connector for connecting the angle detector.
E48 Connector for angle detection unconnected Displayed if the lever is operated with the connector for connecting the angle detector unconnected when the boom status is "jib setting".
E50 Broken or short circuit in boom angle  
E55 broken or short circuit in connector for angle detection An error occurs in the connector for connecting the angle detector when the boom status is "jib", "boom operation with jib mounted", "sercher hook", or "boom operation with searcher hook mounted".
F56 Poorly adjusted jib angle and stroke  
E57 Broken or short circuit in jib length sensor  
F58 Jib length offset adjustment value error  
E59 Jib section count detection fault  
F59 Jib section count detection fault  
E60 Derrick sensor error Derrick pressure sensor P1 or P2 malfunctioned.
E61 Broken or short circuit in derrick pressure sensor P1  
E62 SL jib derrick pressure sensor error The SL jib derrick pressure sensor P1 or P2 is faulty.
E63 Broken or short circuit in SL jib derrick pressure sensor P1  
E64 Rotation sticking error in the winch lowering direction when the main winch lever is operated in the hoisting direction  
E65 Rotation sticking error in the winch hoisting direction when the main winch lever is operated in the lowering direction  
E66 Rotation sticking error in the winch hoisting direction when the main winch lever is operated in the neutral position  
E67 Rotation sticking error in the winch lowering direction when the auxiliary winch lever is operated in the hoisting direction  
E68 Rotation sticking error in the winch hoisting direction when the auxiliary winch lever is operated in the lowering direction  
E69 Rotation sticking error in the winch hoisting direction when the auxiliary winch lever is operated in the neutral position  
E71 Derrick pressure sensor P2 error  
F72 Broken or short circuit SL jib derrick pressure sensor P2  
E73 Main winch control lever sticking error  
E74 Auxiliary winch control lever sticking error  
E76 Boom extension/retraction control lever sticking error  
E77 Jib derricking/lowering control lever sticking error  
E78 Jib extension/retraction control lever sticking error  
E80 Broken circuit in slewing angle sensor  
E81 Broken circuit in slewing encoder signal A  
E82 Broken circuit in slewing encoder signal B  
E84 Broken or short circuit in slewing potentiometer  
F84 Broken or short circuit in slewing potentiometer  
E85 Slewing potentiometer standard point error  
F85 Slewing potentimeter reference point failure  
E86 Slewing potentiometer error  
F86 Slewing potentiometer voltage failure  
F87 Slewing front switc error  
F88 Slewing zero adjustment error  
F89 Slewing encoder and potentiometer angles are inconsistent.  
E90 Open top terminal communication circuit  
F90 Open top terminal communication circuit  
E91 Communication error with top terminal  
F91 Communication error with top terminal  
F95 Crane serial No. not specified in EEPROM  
F96 Main unit time reading error Cannot read the main unit time
F97 Battery voltage is 20V or less  
F98 Backup power supply wiring error Backup power supply voltage 5 volts or less, due to broken or short circuit.
F99 Overload date memory area is full No or minimal memory space is aviailable, because more then the specified number or overload date values were recorded.
No. name description